Review



polished tapered cemented femoral stem exeter v40  (Stryker)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Stryker polished tapered cemented femoral stem exeter v40
    Polished Tapered Cemented Femoral Stem Exeter V40, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/exeter++total+hip+system/pmc12192544-28-21-24
    Average 90 stars, based on 1 article reviews
    polished tapered cemented femoral stem exeter v40 - by Bioz Stars, 2026-09
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Increasing age does not influence hip-specific functional outcome or health-related quality of life following total hip arthroplasty
    Article Snippet: A cemented Exeter stem was used for all with a 32 mm femoral head and a X3 (RimFit) cemented polyethylene socket (Stryker Orthopaedics, USA).

    Article Title: Robotic arm-assisted versus manual total hip arthroplasty
    Article Snippet: All patients received a cemented Exeter stem (Stryker), which was inserted using third-generation cementing techniques.

    Article Title: The Health‐Related Quality of Life for Cemented Versus Uncemented Hemiarthroplasty in Elderly Patients With Femoral Neck Fractures: A Systematic Review and Meta‐Analysis of Randomized Controlled Trials
    Article Snippet: Inngul 2015 (A) , Sweden , 39/44 , NA , NA , NA , Cemented Exeter stem (Stryker, Kalamazoo, Michigan) with a unipolar head , Cementless hydroxyapatite‐coated unipolar head , 1.

    Article Title: A Cost-Utility Analysis of Robotic Arm-Assisted Total Hip Arthroplasty: Using Robotic Data from the Private Sector and Manual Data from the National Health Service
    Article Snippet: All patients received a cemented Exeter stem (Stryker, Newbury, UK), which was inserted using fourth-generation cementing techniques.

    Article Title: The influence of anterior and posterior knot placement on hip function after total hip arthroplasty using a modified Dall's approach: a prospective non-randomised comparative study.
    Article Snippet: Background: The direct lateral modified Dall’s approach for total hip arthroplasty (THA) provides an excellent vision of the hip joint by osteotomising the greater trochanter (GT).. A robust method for the reattachment of osteotomised fragments is essential to prevent complications around the GT.. Ultra-high molecular weight polyethylene cables are reported to be useful for reattachment; but the optimal suture method of these cables is unknown.

    Article Title: Higher rate of complications with uncemented compared to cemented total hip arthroplasty for displaced intracapsular hip fractures: A randomised controlled trial of 50 patients
    Article Snippet: The cemented group received cemented Exeter stem with a contemporary cemented polyethylene cup (Stryker Orthopaedics, Mahwah, New Jersey, USA).

    Migration:

    Article Title: Mid-Term Migration Pattern of a Cemented Collared Anatomical Stem—A Retrospective Study Using EBRA-FCA
    Article Snippet: .. In their RSA study, Nieuwenhuijse et al. reported a mean distal migration of the cemented Exeter stem (Stryker, Kalamazoo, MI, USA) of 2.13 mm after a ten-year follow-up, whereas the stem continued to migrate during the whole first decade after implantation [ ]. ..



    Similar Products

    90
    Stryker polished tapered cemented femoral stem exeter v40
    Polished Tapered Cemented Femoral Stem Exeter V40, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/exeter++total+hip+system/pmc12192544-28-21-24
    Average 90 stars, based on 1 article reviews
    polished tapered cemented femoral stem exeter v40 - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Stryker cemented polished taper slip (pts) exeter stem
    Cemented Polished Taper Slip (Pts) Exeter Stem, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/cemented+polished+taper+slip++pts++exeter+stem/pmc12192544-21-19-33
    Average 90 stars, based on 1 article reviews
    cemented polished taper slip (pts) exeter stem - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Stryker exeter v40 cemented femoral stems
    Exeter V40 Cemented Femoral Stems, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/exeter++total+hip+system/pmc12192544-0-26-28
    Average 90 stars, based on 1 article reviews
    exeter v40 cemented femoral stems - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Stryker cemented exeter universal stem
    Cemented Exeter Universal Stem, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/cemented+exeter+universal+stem/pmc12092379-44-35-95
    Average 90 stars, based on 1 article reviews
    cemented exeter universal stem - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Stryker exeter® v40 cemented stem
    Exeter® V40 Cemented Stem, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/exeter++total+hip+system/pmc12064231-51-35-39
    Average 90 stars, based on 1 article reviews
    exeter® v40 cemented stem - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Stryker exeter cemented stem
    Exeter Cemented Stem, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/cemented+exeter+stem/pmc12072643-4-25-30
    Average 90 stars, based on 1 article reviews
    exeter cemented stem - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Stryker cemented polished taper-slip stem exeter v40
    Cemented Polished Taper Slip Stem Exeter V40, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/exeter+polished+tapered+stem/pm40237859-61-5-10
    Average 90 stars, based on 1 article reviews
    cemented polished taper-slip stem exeter v40 - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Stryker cemented v40 exeter stem, size #1, offset
    Prior case reports demographics, index, and revision procedures.
    Cemented V40 Exeter Stem, Size #1, Offset, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/triathlon+pkr+peg+drill+size+1+2/pmc11869593-4-35-34
    Average 90 stars, based on 1 article reviews
    cemented v40 exeter stem, size #1, offset - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Stryker cemented exeter stem
    Baseline characteristics of included studies ( n = 20).
    Cemented Exeter Stem, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/cemented+exeter+stem/pmc11787973-7-15-17
    Average 90 stars, based on 1 article reviews
    cemented exeter stem - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Stryker cemented exeter femoral stem
    Baseline characteristics of included studies ( n = 20).
    Cemented Exeter Femoral Stem, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/cemented+exeter+stem/exeter++total+hip+system/pmc11633315-57-8-9
    Average 90 stars, based on 1 article reviews
    cemented exeter femoral stem - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    Prior case reports demographics, index, and revision procedures.

    Journal: Arthroplasty Today

    Article Title: Fourth-generation Ceramic Head Fracture in Total Hip Arthroplasty: A Case Report and Literature Review

    doi: 10.1016/j.artd.2025.101614

    Figure Lengend Snippet: Prior case reports demographics, index, and revision procedures.

    Article Snippet: Rankin et al. [ ] , 2019 , 52 , M , 26 , Primary hip osteoarthritis , NR , CoP , 32 mm inner diameter, 52 mm Trident Tritanium shell , 32 , Stryker cemented V40 Exeter stem, size #1, 50 mm offset , 8 , Traumatic fall with unremarkable radiographs, 1 month later he noticed a sudden sharp pain and sensation of grinding following swimming , CoC , 32 , Cement-in-cement revision with a new 50 mm offset, no. 1 Exeter stem , Metal shell.

    Techniques: Activity Assay

    Prior large review papers on ceramic total hip arthroplasty–preoperative diagnosis and implant information.

    Journal: Arthroplasty Today

    Article Title: Fourth-generation Ceramic Head Fracture in Total Hip Arthroplasty: A Case Report and Literature Review

    doi: 10.1016/j.artd.2025.101614

    Figure Lengend Snippet: Prior large review papers on ceramic total hip arthroplasty–preoperative diagnosis and implant information.

    Article Snippet: Rankin et al. [ ] , 2019 , 52 , M , 26 , Primary hip osteoarthritis , NR , CoP , 32 mm inner diameter, 52 mm Trident Tritanium shell , 32 , Stryker cemented V40 Exeter stem, size #1, 50 mm offset , 8 , Traumatic fall with unremarkable radiographs, 1 month later he noticed a sudden sharp pain and sensation of grinding following swimming , CoC , 32 , Cement-in-cement revision with a new 50 mm offset, no. 1 Exeter stem , Metal shell.

    Techniques: Biomarker Discovery, Modification

    Baseline characteristics of included studies ( n = 20).

    Journal: Orthopaedic Surgery

    Article Title: The Health‐Related Quality of Life for Cemented Versus Uncemented Hemiarthroplasty in Elderly Patients With Femoral Neck Fractures: A Systematic Review and Meta‐Analysis of Randomized Controlled Trials

    doi: 10.1111/os.14339

    Figure Lengend Snippet: Baseline characteristics of included studies ( n = 20).

    Article Snippet: Inngul 2015 (A) , Sweden , 39/44 , NA , NA , NA , Cemented Exeter stem (Stryker, Kalamazoo, Michigan) with a unipolar head , Cementless hydroxyapatite‐coated unipolar head , 1.

    Techniques: